Adler 767 Manuel d'instructions

Naviguer en ligne ou télécharger Manuel d'instructions pour Machines à coudre Adler 767. Adler 767 Instruction manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - CONTROL DA321G5321

FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS GMBH & CO KG SINGAPORE PTE. LTD. dc1550 CONTROL DA32

Page 2 - Important Notes

Instruction Manual - 10 - 5 Setting the Basic Functions 5.1 Direction of motor rotation Function with or without control panel Parameter Direction o

Page 3 - CONTENTS Page

- DA321G5321 - 11 - 5.3 Selection of the machine series Function with or without control panel Parameter Display of the machine series (SEL) 280

Page 4

Instruction Manual - 12 - 5.3.1.1 Configuration instructions for high lift for walking foot for older Dürkopp Adler sewing machines (class 467/767) p

Page 5

- DA321G5321 - 13 - NOTE If no valid select resistor is detected upon commissioning or after a master reset and parameter 290 = 0, no valid mode i

Page 6 - 2 Scope of Supply

Instruction Manual - 14 - 5.7 Maximum speed Function with or without control panel Parameter Maximum speed (n2) 111 NOTE See instruction manual of t

Page 7 - 2.1 Special Accessories

- DA321G5321 - 15 - Connection of a sensor as a position transmitter (normally open contact function), e. g. light barrier to socket B18/7 The foll

Page 8 - Routine (SIR)

Instruction Manual - 16 - Connection of a sensor as apposition transmitter (normally closed contact function), e. g. light barrier or proximity switch

Page 9

- DA321G5321 - 17 - Setting the reference position on the control  Input code number and select parameter 170!  Press the E key  Display Sr1 

Page 10 - TTENTION

Instruction Manual - 18 - >> Press key >> (B key). Display of the 1st parameter value of position 1  P 1 E 0 0 0 + - If necess

Page 11 - - DA321G5321

- DA321G5321 - 19 - P P Settings are completed, exit programming!  4000 dA321G NOTE When setting the positions by turning the handwheel,

Page 12

Important Notes The particulars used in various figures and tables, such as type, program number, speed, etc., serve as examples. They may diff

Page 13

Instruction Manual - 20 - 5.10 Positioning shift Function with or without control panel Parameter Positioning shift (PSv) 269 Parameter 269 can be

Page 14

- DA321G5321 - 21 - If parameter 139 = 1, the V810/820 display shows the following information: V810 V820/V850 During operation:  The actual

Page 15

Instruction Manual - 22 -  Press the E key  000 (milliseconds display)  Press the E key  rES see chapter "Set and Reset Operating Hours Cou

Page 16 - Instruction Manual

- DA321G5321 - 23 - 6 Functions with or without Control Panel 6.1 Softstart Function with or without control panel Parameter Softstart On/Off Sof

Page 17

Instruction Manual - 24 - automatically by stitch counting when pedal forwards, according to the setting of parameter 023 Switch-on delay after th

Page 18

- DA321G5321 - 25 - 6.3 Start backtack Function without control panel Control Single start backtack Double start backtack Start backtack Off Segme

Page 19

Instruction Manual - 26 - 6.3.3 Stitch Correction and Speed Release Function with or without control panel Parameter Stitch correction time Delay unt

Page 20

- DA321G5321 - 27 - Parameter 137 can be used to select the stitch length (normal or long stitch) during the backtack. The display does not light u

Page 21

Instruction Manual - 28 - 6.4.6 Backtack Synchronization Function with or without control panel Parameter Backtack synchronization for the end backta

Page 22

- DA321G5321 - 29 - 6.6 End ornamental backtack Function without control panel Control Single end ornamental backtack Double end ornamental backta

Page 23 - 6.2 Sewing foot lifting

- DA321G5321 - 3 - CONTENTS Page 1 Range of Applications 6 1.1 Use in Accordance with Regulations 6 2 Scope of Supply 6 2.1 Special Acces

Page 24 - ATTENTION

Instruction Manual - 30 - 6.8 Catch backtack Function with or without control panel Parameter Number of forward stitches of catch backtack Number of

Page 25 - 6.3 Start backtack

- DA321G5321 - 31 - After expiration of the ornamental backtack stop period, the previously counted stitch count is repeated forward if this functi

Page 26

Instruction Manual - 32 - 6.14 Machine run blockage ATTENTION This is not a safety function. The line voltage must still be switched off during main

Page 27

- DA321G5321 - 33 - In the free seam:  Fastest possible stop without positioning.  Trimming is not possible.  After lifting of the machine ru

Page 28

Instruction Manual - 34 - 6.15 Bobbin thread monitor Function with or without control panel Parameter Stitch count for bobbin thread monitor (paramet

Page 29 -  Multiple backtack

- DA321G5321 - 35 - The following exceptions should be noted:  If the bobbin thread monitor ends in a start backtack, then the start backtack wil

Page 30

Instruction Manual - 36 - Resetting the stitch counter (A, B, or C) Short actuation of the key (<1 sec.) sets the currently selected stitch counter

Page 31

- DA321G5321 - 37 - 6.17.2 Switch stitch length (Function module A) Function with or without control panel Parameter Stitch length switching with

Page 32 - - S t o P

Instruction Manual - 38 -  After power-on, output A and LED A are turned on.  A key movement after power-on before sewing starts turns off output

Page 33

- DA321G5321 - 39 - 6.17.5 Lift / lower material stop (Function module A) Function with or without control panel Parameter Raise/lower material st

Page 34

Instruction Manual - 4 - 6.6 End ornamental backtack 29 6.7 Multiple backtack 29 6.8 Catch backtack 30 6.9 Triple end backtack 30 6.10 Interm

Page 35

Instruction Manual - 40 - 6.17.7 Edge trimmer manual (Function module A) Function with or without control panel Parameter Edge trimmer manual (output

Page 36

- DA321G5321 - 41 - Automatic operation: Parameter 253 > 0, 254 > 0, 251 = 0 Output A LED A Remark power On Off Off Press key A before th

Page 37

Instruction Manual - 42 - Manual operation: Parameter 253 = 0, 254 = 0, 251 = 0 Output A LED A Remark power On Off Off Press key A at seam start or

Page 38

- DA321G5321 - 43 - Function with control panel Parameter high lift for walking foot ratcheting = 1 / temporary = 0 (-F-) 008 = 3 6.17.10 Sewing

Page 39

Instruction Manual - 44 - 6.17.13 Backtack suppression / backtack call (Function module A) Function with or without control panel Parameter Backtack s

Page 40

- DA321G5321 - 45 - 6.19.2 Analogous speed limitation The maximum speed can be limited by an analog voltage on input A/3. The analog voltage is ge

Page 41

Instruction Manual - 46 - F2 Press the F2 key!  ZZZZ XX AB YY  Set high lift for walking foot (potentiometer on the machine) to the level u

Page 42

- DA321G5321 - 47 - 6.20 Thread trimming operation Function with or without control panel Parameter Thread trimmer On/Off Thread wiper On/Off (FA)

Page 43

Instruction Manual - 48 - The thread tension release signal can be turned on with a delay relative to the thread trimmer. The delay is entered as an a

Page 44

- DA321G5321 - 49 - 6.23 Thread wiper/Short trimmer The thread wiper signal is turned on after position 2 is reached for a time set in parameter 2

Page 45

- DA321G5321 - 5 - 6.27 Free Seam and Seam with Light Barrier 51 6.28 Light barrier 51 6.28.1 Speed after Light Barrier Sensing 51 6.28.2 Ge

Page 46

Instruction Manual - 50 - 6.25 Seam with Stitch Counting Function without control panel Parameter Stitch counting On/Off (StS) 015 Function with con

Page 47 - 6.21 Thread tension release

- DA321G5321 - 51 - 6.26 Plugging Function with control panel V820/V850 parameter Seam end in plug program execution (dkn) 322 = 3 The plugging f

Page 48

Instruction Manual - 52 - 6.28.2 General Light Barrier Functions Function with or without control panel Parameter Light barrier compensation stitches

Page 49

- DA321G5321 - 53 - 6.28.5 Light barrier filter for knitted fabrics Function with or without control panel Parameter Number of stitches of the lig

Page 50

Instruction Manual - 54 - 16 Intermediate backtack / intermediate stitch condensing: Upon pressing the key, the backtack or stitch condensing will be

Page 51

- DA321G5321 - 55 - 6.30 Key block Function with or without control panel Parameter Select the slide-in strip number for the V810 control panel (2

Page 52

Instruction Manual - 56 - 6.32 Signals A1 and A2 When using the V820/V850 control panel, direct access by means of the function key (key 9) is possib

Page 53

- DA321G5321 - 57 - Using parameter 330 for signal A1 and parameter 335 for signal A2, it is possible to select if these signals and sewing foot li

Page 54

Instruction Manual - 58 - Function with or without control panel Parameter Speed stage graduation (nSt) 119 The pedal characteristics (speed change

Page 55 - 6.30 Key block

- DA321G5321 - 59 - 6.35 Masterreset Restoration of the preset values set at the factory. Operating and display example for V820 P Press and

Page 56 - 6.32 Signals A1 and A2

Instruction Manual - 6 - 1 Range of Applications The drive is suitable for lockstitch and chainstitch machines Dürkopp Adler, for different models. I

Page 57 - 6.33.1 Digital actuator

Instruction Manual - 60 - 7 Signal Test Function with or without control panel Parameter Input and output test (Sr4) 173 Function test of externa

Page 58 - 6.34 Acoustic Signal

- DA321G5321 - 61 - 7.1.2 Outputs of control  Select parameter 173.  Select the desired output using the +/- keys.  On the V810 control pane

Page 59

Instruction Manual - 62 - For your notes:

Page 60 - 7 Signal Test

- DA321G5321 - 63 - For your notes:

Page 61

FRANKL & KIRCHNER GMBH & CO KG SCHEFFELSTRASSE 73 – 68723 SCHWETZINGEN TEL.: +49-6202-2020 – FAX: +49-6202-202115 E-Mail: [email protected]

Page 62

- DA321G5321 - 7 - 2.1 Special Accessories The special accessories available ex works allow the augmentation and enhancement of functions, operati

Page 63

Instruction Manual - 8 - F-290End SIRF-272Pos 0 F-161PEEEPEF-280F-500Code 3112F-200EEENoYesKL2547>>>>F-1703 Putting into Service Before

Page 64 - OF AMERICA INC

- DA321G5321 - 9 - Function Control Call-up of the Fast Installation Routine SIR (Sir) 500 Setting on the V810 control panel:  Input code numb

Commentaires sur ces manuels

Pas de commentaire